|
Datos del producto:
|
| Nombre: | Sensor de presión | Modelo: | Piezas de coche |
|---|---|---|---|
| Transporte: | DHL TNT FEDEX | Nombre del producto: | Sensor de presión |
| Producto: | Sensor de presión | tipo: | Sensor de presión |
| Carga nominal: | 1000 / 3000 / 5000kg | Longitud del cable: | 5m |
| Impedancia del aislamiento: | ≥5000MΩ | Tamaño: | 150 × 48 × 35 milímetros |
| Clase de protección: | IP67 / IP68 |
Elevator Electrical Pressure Sensor Convenient And Reliable For Installation
The elastic structure of the sensor is special, with good bending and torsion resistance, thereby improving the natural frequency and anti overturning, anti deviation, anti-interference and other characteristics of the sensor. The installation and connection of the sensor can use specialized connecting components, which is convenient and reliable for installation.
| Rated load | 1000 / 3000 / 5000kg |
| Sensitivity | 2.0±0.02%mV/V |
| Total error | ±0.5% F.S |
| Creep error | ±0.02% F.S |
| TC SPAN | ±0.02% F.S / 10℃ |
| Working temperature | -20~+60℃ |
| Input impedance | 760±10Ω |
| Output impedance | 700±2Ω |
| Safe overload | 150% F.S |
| Ultimate overload | 200% F.S |
| Excitation | 5~12VDC |
| Max.excitation | 15VDC |
| Insulation impedance | ≥5000MΩ |
| Protection class |
IP67 / IP68
|
| Construction | Alloy Steel |
| Size | 150 × 48 × 35 mm |
| Cable length | 5m |
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.
Persona de Contacto: Mr. Wei CHEN
Teléfono: +86-13661864321
Fax: 86-021-59168286