50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay

50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay
50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay

Ampliación de imagen :  50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay

Datos del producto:
Lugar de origen: Porcelana
Nombre de la marca: SUNNY
Certificación: CE,ISO9001
Número de modelo: SN-RD6-W
Pago y Envío Términos:
Cantidad de orden mínima: 1 Uds.
Precio: $20~100
Detalles de empaquetado: paquete de exportación estándar
Tiempo de entrega: 7~15 días
Condiciones de pago: Western Union, T/T, L/C, Paypal
Capacidad de la fuente: mes de 1000 PC

50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay

descripción
Nombre: Relé de monitoreo de voltaje de 3 fases tipo: Relé de monitoreo de voltaje de 3 fases
Voltaje: 200 ... 500 VCA Modelo: Relé de monitoreo de voltaje de 3 fases
Producto: Relé de monitoreo de voltaje de 3 fases Frecuencia nominal: 50/60Hz±1Hz
Material de contacto: Agsno Temperatura: -20 ... +60 ℃
Nivel de protección: IP40 Gama de la exhibición de voltaje: 150 ... 500 VCA
Tamaño: 80 × 43 × 54 milímetros

 

50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay

 

Main features

 

◼︎ One unit can monitor voltage imbalance, phase sequence, and under phase of three-phase 3-wire or 4-wire power supplies

◼︎ Switch settings for 3-phase or 3-wire or 4-wire power supplies

◼︎ 1 SPDT output relay, 6A at 250VAC (resistive load)

◼︎ 1 unit supports power specifications from around the world (switchable)

◼︎ Convenient monitoring of relay alarm status using LED indicators

 

Data sheet

 

Rated voltage 200 ... 500VAC
Rated frequency 50/60Hz±1Hz
Contact type 2NO / 1NC
Contact material AgSnO
Contact rating 5A 280VAC / 8A 30VDC
Contact life 2×10
Temperature -20 ... +60℃
Phase imbalance
≤10%
Insulation voltage 2.5KV / 1mn / 1mA / 50Hz
Protection level IP40
Voltage action setting time 0.1 ... 20s
Phase loss and error time 0.1 ... 20s
Overcurrent setting value
-
Indicator Display
Voltage display range 150 ... 500V AC
Maximum Counting 999999
Maximum timing capacity
9999 hours and 59 minutes
Timing input signal Active24V,110V,220V or 380V
Data retention time 18 years
Size 80 × 43 × 54 mm

 

 

50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay 0

 

50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay 1

50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay 2

 

FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.

Contacto
SHANGHAI SUNNY ELEVATOR CO.,LTD

Persona de Contacto: Mr. Wei CHEN

Teléfono: +86-13661864321

Fax: 86-021-59168286

Envíe su pregunta directamente a nosotros (0 / 3000)